Oregon foundation repair & home remodelingCCB #227476 Se habla español
541-543-8328Free estimate
← Oregon foundation repair questions

Do empty holes in a floor joist hanger mean required fasteners are missing?

Some empty holes matter immediately. Others belong to an optional fastening pattern. Identify the stamped connector model, the wood members it joins and the pattern the project requires. For example, Simpson Strong-Tie directs installers to fill the round holes in its HUS guide. Its HUC product page identifies extra triangular holes for additional load. Even on that second product, whether the additional fasteners matter depends on the load and schedule the designer used. HUS installation guide and HUC product information.

Photograph the connection from two directions

First take a wide view identifying the supported joist, the supporting header or beam, and the bay’s location. Then photograph the hanger face and the sides accessible without disturbing framing. Record the stamp exactly, including suffixes. Show which empty holes are in the flange fastened to the header and which are beside the joist. A photograph straight into the joist end can hide an entire row of side fasteners. If pipes or insulation obscure one flange, identify the concealed portion in the report.

The two sets of fasteners do different work. In a double-shear hanger with angled joist fasteners, the manufacturer relies on a prescribed fastener path through the joist into the supporting member. Seeing heads in the openings establishes neither their penetration nor their diameter. Mark an identifiable screw head or an exposed shank separately from a fastener whose type you can only guess. Record splits in the wood, a gap under the joist seat, or a flange pulled away from the header as distinct findings. Adding a nail would leave those conditions unresolved. Manufacturer’s double-shear LUS installation illustrations.

Example inspection wording

At the first floor joist east of the basement stairs, two round openings in the visible header flange were empty. The connector stamp was obscured and the far side was inaccessible. Obtain the connector identification and applicable fastening schedule. Have the contractor compare the installation with that detail and document any correction.

Where the model and required pattern are verified, identify the exact discrepancy and attach the corresponding illustration. If the seat is separating or the supported wood is splitting, request prompt structural review before adding load above. For an Oregon joist and beam repair estimate, call Home Remodel Specialist at 541-543-8328.

Request a free estimate ↗
© 2026 Home Remodel Specialist · OregonPrivacy & project inquiries